  Mortar Safety Guidelines




Camp W.G. Williams
 
 

SHORT ROUND AND MISFIRE PROCEDURES FOR CARTRIDGES, 81MM, HE M889/M821

//UNCLASSIFIED//

102028Z DEC 08

USE THIS DTG TO REFERENCE THIS MESSAGE

FROM CDR JMC ROCK ISL IL//AMSJM-QAS//

740 (A)

SUBJECT: AMMUNITION INFORMATION NOTICE (AIN) 023-09, SHORT

ROUND AND MISFIRE PROCEDURES FOR CARTRIDGES, 81MM, HE M889/M821

(1315-C869/C868)



A. AR 75-1, MALFUNCTIONS INVOLVING AMMUNITION AND

EXPLOSIVES (RCS GSLD-1961 (MI)), 04 NOV 08.



1. AIN 022-09 WAS TRANSMITTED ON 102025Z DEC 08.



2. THIS AIN SUPERSEDES AIN 150-07.



3. REQUEST DISSEMINATION OF THIS AIN TO ALL UNITS FIRING

81MM MORTARS, RANGE SAFETY OFFICERS AND EOD.



4. RARE INSTANCES OF SHORT ROUNDS AND MISFIRES MAY BE

EXPECTED WITH SUBJECT CARTRIDGES MANUFACTURED PRIOR TO

NOVEMBER 1989. CAUSE IS BLOCKAGE OF PRIMER FLASH HOLE BY

SEALING COMPOUND UTILIZED IN MANUFACTURE. TESTING HAS

DETERMINED SHORT ROUNDS CAUSED BY THIS DEFECT WILL FALL AS

SHORT AS 3.5 FEET AND AS FAR AS 140 FEET FROM WEAPON.

ASSEMBLED FUZES, PD, M935 AND MULTI-OPTION, M734 NORMALLY DO

NOT ARM WITHIN THIS RANGE OR FUNCTION UPON IMPACT.



5. FOLLOWING PROCEDURES APPLY TO SHORT ROUNDS:



A. GUN CREWS EXPERIENCING SHORT ROUNDS DESCRIBED IN PARA 4

MUST EVACUATE FIRING POSITION DUE TO REMOTE POSSIBILITY FOR

FUZE ARMING. EOD MUST ACCOMPLISH DISPOSAL OF DUDS.



B. REQUEST THAT FIRING UNIT SUBMIT AN AMMUNITION MALFUNCTION

REPORT, DA FORM 4379. INCLUDE INFORMATION FROM EOD ON THE

PRESENCE OF UNBURNED PROPELLANT OR OTHER UNUSUAL CONDITIONS

AND INCLUDE PHOTOGRAPHS AND OBSERVATIONS INTO REPORT.



6. FOLLOWING PROCEDURES SHOULD BE UTILIZED FOR MISFIRES:



A. IF ACTUAL RATE DOES NOT MEET REPORTABLE RATE SPECIFIED IN

TABLE B-1 OF REFERENCE, MISFIRES SHOULD BE REPACKED,

CONTAINERS MARKED "MISFIRES", AND RETURNED TO AMMUNITION

SUPPLY POINT. QUALITY ASSURANCE SPECIALIST, AMMUNITION

SURVEILLANCE (QASAS) SHOULD INSPECT MISFIRES, REPORT

OBSERVATIONS (TO INCLUDE PHOTOGRAPHS) IF POWDER BURNS ARE

FOUND AROUND PRIMER HOUSING, OR PROPELLANT IS FOUND TO BE

SCORCHED. THESE CONDITIONS ARE INDICATIVE OF BLOCKED FLASH

HOLE.



B. IF ACTUAL RATE MEETS OR EXCEEDS REPORTABLE RATE

IMMEDIATELY REPORT MALFUNCTION AND TAKE OTHER ACTION AS

REQUIRED BY PARA 2-1 OF REFERENCE. QASAS SHOULD INSPECT

MISFIRED ROUNDS, AS IN PARA 6A.



7. ABOVE REQUIREMENTS ARE IN ADDITION TO, NOT IN LIEU OF,

ACTIONS REQUIRED BY REFERENCE.



8. POINT OF CONTACT IS MR KYLE VOELCKER, AMSJM-QAS, DSN

793-3151, (309) 782-3151, E-MAIL KYLE.VOELCKER@US.ARMY.MIL.



9. THIS AIN EXPIRES 31 DEC 09 UNLESS OTHERWISE RESCINDED OR

SUPERSEDED.









//SIGNED//

LEWIS H. KOPERA

CHIEF, AMMUNITION SURVEILLANCE DIVISION