Copyright 2004
Army Garrison Camp Williams
( all rights reserved )

 USE OF SIMULATOR, HAND GRENADE, M116A1 (DODAC 1370-L601)

//UNCLASSIFIED//
 

171850Z JUL09

FROM CDR USAJMC ROCK ISL IL//AMSJM-QAS// 740(A)

SUBJECT: AMMUNITION INFORMATION NOTICE (AIN) 097-09, USE OF SIMULATOR, HAND GRENADE, M116A1 (DODAC 1370-L601)

1. AIN 096-09 WAS TRANSMITTED ON 151242Z JUL 09.

2. THIS AIN SUPERSEDES AIN 47-08.

3. REFERENCES:

A. TM 9-1370-207-10, W/C7, PYROTECHNIC SIMULATORS, 14 SEPTEMBER 2006.

B. MIL-STD-1168B, AMMUNITION LOT NUMBERING AND AMMUNITION DATA CARDS, 10 JUNE 1998

4. DISSEMINATE TO ALL PERSONNEL RESPONSIBLE FOR HANDLING, STORING AND USING SIMULATOR, HAND GRENADE,
M116A1 (DODAC 1370-L601).

5. RECENT MALFUNCTION REPORTS INDICATE END CAPS FROM LOTS PRODUCED AFTER JAN 2006 ARE TRAVELING UP TO 30 METERS FROM POINT OF FUNCTIONING. THESE REPORTS HAVE BEEN CONFIRMED BY THE ARDEC TECHNICAL COMMUNITY.
ADDITIONAL TESTING IS CURRENTLY ONGOING IN AN ATTEMPT TO REDUCE L601 SURFACE DANGER ZONE (SDZ). ARDEC PYROTECHNICS RESEARCH AND TECHNOLOGY BRANCH, ARDEC AMMO MAINTENANCE ENGINEERING BRANCH, PM-CCS, JMC QA, JMC SAFETY AND JMC COMMODITY TEAM CONCUR WITH 30 METER SDZ FOR LOTS PRODUCED AFTER JAN 2006 FOR UNPROTECTED PERSONNEL UNTIL ADDITIONAL TESTING IS COMPLETED.

6. LOT IDENTIFICATION AND REPORTING FOR M116A1 SIMULATORS (L601):

A. USERS CAN DETERMINE YEAR OF MANUFACTURE BY DECIPHERING FOURTH, FIFTH, AND SIXTH DIGITS OF THE LOT NUMBER AS IN FOLLOWING EXAMPLES:

1) FEBRUARY 2005 LOTS - PBG05B001-001 WHERE 05 INDICATES YEAR OF MANUFACTURE (2005) AND B IDENTIFIES MONTH OF MANUFACTURE (FEBRUARY).

2) JULY 2006 LOTS - PBG06G001-001 WHERE 06 INDICATES YEAR OF MANUFACTURE (2006) AND G IDENTIFIES MONTH OF MANUFACTURE (JULY).

3) REFERENCE B PROVIDES ADDITIONAL LOT NUMBERING GUIDANCE.

7. SDZ FOR M116A1 SIMULATORS (L601):

YEAR OF MANUFACTURE: SURFACE DANGER ZONES:
NEWER THAN JAN 2006 30 METERS � CHANGED 1 MAR 08

A. LOTS MANUFACTURED PRIOR TO JANUARY 2006 HAVE BEEN RECLASSIFIED TO CC-H, PERMANENTLY SUSPENDED FROM ISSUE AND USE. (SEE TB 9-1300-385, NAR 08-0179).

B. LOTS MANUFACTURED AFTER JANUARY 2006 HAVE A 30 METERS SDZ. USE OF THESE LOTS WILL BE IAW REFERENCE A.
INSPECTORS WILL RETAIN ASSETS IN CURRENT CONDITION CODES.

8. IT IS IMPERATIVE USERS FOLLOW ALL GUIDELINES, PRECAUTIONS, AND WARNINGS CONTAINED IN REFERENCE

A.  SPECIFICALLY, WHEN A SIMULATOR IS INITIATED, IT MUST BE IMMEDIATELY THROWN IN A DIRECTION AWAY FROM UNPROTECTED PERSONNEL.

10. ADDITIONAL GUIDANCE:

A. ////WARNING//// THESE DEVICES SHALL NOT BE ACTIVATED IN LOOSE GRAVEL, DEBRIS, OR OTHER MATERIALS THAT ARE SUBJECT TO PROJECTION. ALSO THEY SHOULD NOT BE THROWN INTO DRY LEAVES, GRASS, OR OTHER FLAMMABLES.

B. QASAS WILL ENSURE DA FORM 581 USED TO ISSUE L601 LOTS MANUFACTURED AFTER JANUARY 2006 WILL BE
ANNOTATED: �DODIC L601 ISSUED ON THIS DOCUMENT HAS A 30 METER SDZ AND MUST BE USED IAW TM 9-1370-207-10 AND AIN XXX-09�

C. RESTRICT USE AND HANDLING OF SIMULATORS TO DESIGNATED, AUTHORIZED PERSONNEL. PERSONNEL SHALL BE LIMITED TO EXPERIENCED, THOROUGHLY TRAINED COMBAT TRAINERS/CONTROLLERS WHO HAVE BEEN BRIEFED ON POTENTIAL HAZARDS OF THESE ITEMS INCLUDING AND ESPECIALLY 30 METER SDZ.

D. OBSERVE SDZ FROM UNPROTECTED PERSONNEL AT ALL TIMES. SDZ DISTANCES LESS THAN 30 METERS ARE ONLY ACCEPTABLE FOR PROTECTED PERSONNEL. PROTECTED PERSONNEL ARE THOSE PROTECTED BY SUITABLE COVER, SUCH AS ARMORED VEHICLES, BUILDINGS, OR DUG-IN EMPLACEMENTS ETC. FURTHERMORE, PERSONNEL ARE NORMALLY CONSIDERED PROTECTED WHEN SIMULATOR DETONATIONS ARE SEPARATED FROM PERSONNEL BY MASKING TERRAIN OR WITHIN DESIGNATED BARRICADED AREAS AND/OR PITS. COMBAT TRAINERS/CONTROLLERS SHALL WORK DIRECTLY WITH LOCAL SAFETY AND QASAS PERSONNEL TO EVALUATE, DESIGN, AND/OR APPROVE LOCATIONS ON THE TRAINING RANGE FOR SIMULATOR USE.

11. PERSONNEL PROTECTION:

A. THROWERS: PERSONNEL DESIGNATED AND AUTHORIZED TO USE SIMULATORS SHALL FOLLOW PRECAUTIONS AND WARNINGS IN REFERENCE A. WHEN USING M116A1 SIMULATORS, THROWER SHALL WEAR:

1) STANDARD-ISSUE LEATHER GLOVE ON THROWING HAND.

2) SAFETY EYEWEAR (E.G., "GARGOYLE" EYEWEAR OR SAFETY GLASSES).

3) THROWER SHALL ALSO SEEK SUITABLE COVER/BARRICADE, TURN AWAY FROM SIMULATOR POINT OF DETONATION AND ASSUME PROTECTIVE STANCE AFTER THROWING. THROWER SHALL ALSO ASSURE SIMULATOR IS THROWN AT LEAST 30 METERS FROM UNPROTECTED PERSONNEL.

B. ADDITIONAL SPECIFIC M116A1 SIMULATOR THROWER
GUIDANCE:

1) WILL BE EMPLOYED ONLY FROM BEHIND SUITABLE COVER/BARRICADE.

2) EAR PROTECTION (AS REQUIRED BASED ON THROWER
PROXIMITY TO DETONATION AREA).
 

C. TRAINEES SPECIFIC PERSONNEL PROTECTION REQUIREMENTS EXPOSED TO M116A1 EFFECTS:

1) SAFETY EYEWEAR (E.G., �GARGOYLE� EYEWEAR OR SAFETY GLASSES).

2) KEVLAR HELMET

3) FLACK VEST

D. EXPOSED OR TARGET PERSONNEL WHO ARE NOT UNDER COVER SHALL BE INSTRUCTED TO FOLLOW CURRENT DOCTRINE FOR ACTION NORMALLY TAKEN WHEN EXPOSED IN COMBAT.

12. WHILE USE OF PROPER PRECAUTIONS WILL MITIGATE SAFETY HAZARDS, USERS SHOULD ALSO ASSURE ITEM FUNCTIONING PROBLEMS ARE PROMPTLY REPORTED TO THE APPROPRIATE AMMUNITION SURVEILLANCE OR AMMUNITION LOGISTICS ASSISTANCE REPRESENTATIVE.

13. POC'S ARE: AMMUNTION ENGINEER - MR. MICHAEL VILLACILLO, RDAR-EIL-LM, DSN: 880-2033, MICHAEL.VILLACILLO@US.ARMY.MIL. QASAS - MR. CLARK COMBS, AMSJM-QAS, DSN 793-8485, (309) 782-8485, CLARK.COMBS@US.ARMY.MIL